Lowest allowable CFM without Make up Air, Commercial Kitchen

$10-75 USD

Concluído
Publicado há mais de 5 anos

$10-75 USD

Pago na entrega
Im in the process of opening a bar/tavern in Oregon. Im doing a ventless/hoodless. Building inspector has told me that even if I get rid of cooking equipment and have just my low-temp undercounter dishwasher (which aren't suppose to require it as they don't produce more steam than hot water out of faucet) I will be required to put in a minimum 50 CFM fan. I want to know what the lowest amount of CFM's of exhaust you can have before make up air is required. The math from mechanical code stated .70 CFM per square foot and my kitchen is 100 square feet approximately. My original plan was to have the undercounter dishwasher and 2 pieced of ventless equipment, which are also not suppose to require heat exhaust as they have them built into the equipment, and the math had something about 100 CFM per piece of equipment. I need someone to tell me what the lowest allowable amount of CFMs is before make up air is required to be installed. If its less than 400 I need an engineer to do the math and provide a stamp so that I can submit that to the building inspector and satisfy his need for it. I want to put in a fan that is the lowest allowable amount to help allow me to put the most pieces of equipment I can which sounds like it may only be 2 or 3. Exhaust duct will have one to two elbows and only need to exhaust about 10-15 feet out the side wall of building. I don't know much about this stuff and any help that can get me going is appreciated.
ID do Projeto: 17846704

Sobre o projeto

1 proposta
Projeto remoto
Ativo há 6 anos

Quer ganhar algum dinheiro?

Benefícios de ofertar no Freelancer

Defina seu orçamento e seu prazo
Seja pago pelo seu trabalho
Descreva sua proposta
É grátis para se inscrever e fazer ofertas em trabalhos
Concedido a:
Avatar do Usuário
i am a mechanical engineer and have done a course work on HVAC, also i have done a project that required the HVAC system designed for a 2 floors building. i understand the need of this project since the fresh air requirement in the kitchen is one of the important factor in kitchen design. I can help you in estimating this ventilation requirement with a very powerful tool used in HVAC industry that is named "HAP" (hourly analysis program). I have very good command in using this software also I can use a duct sizing software to help u estimate the ducting in your kitchen. As a final product i will provide you with the fan to be installed for required CFM and any recommendations for a effective small system installation. I assure you of very timely project delivery
$50 USD em 5 dias
0,0 (0 avaliações)
0,0
0,0

Sobre o cliente

Bandeira do(a) UNITED STATES
Seaside, United States
0,0
0
Método de pagamento verificado
Membro desde set. 26, 2018

Verificação do Cliente

Obrigado! Te enviamos um link por e-mail para que você possa reivindicar seu crédito gratuito.
Algo deu errado ao enviar seu e-mail. Por favor, tente novamente.
Usuários Registrados Total de Trabalhos Publicados
Freelancer ® is a registered Trademark of Freelancer Technology Pty Limited (ACN 142 189 759)
Copyright © 2024 Freelancer Technology Pty Limited (ACN 142 189 759)
Carregando pré-visualização
Permissão concedida para Geolocalização.
Sua sessão expirou e você foi desconectado. Por favor, faça login novamente.